Static Relays - Interconnection (GateManager own)


Purpose


This guide will provide information on how you create Static Relays - Interconnection between two SiteManager hardware through GateManager own




Resolution


Scenario:
Computer in one location needs to connect to Camera in a different location.
Computer initiates the communication on port 80. Both SiteManagers are in the same Domain on the
GateManager

Details:

Configuration on the GateManager Server:
Click on the domain where the 2 SiteManagers are located and click the Relay tab.

Domain Relay Settings
Tick the “Use Local Relay Settings” - When this is ticked the relays are not inhered to subdomains.
Tick the “Enable Inter-Device Relays” - Needed when one SiteManager needs to connect another
SiteManager.
Device Relays - Device Virtual Addresses
Here we define the Pool of virtual addresses needed to setup the relay.
In this example we only need one address to achieve our goal.
Device Relay Access Filter
Here we specify the IP address of the harvesting-server which are allowed to access the Device
Relay configured on the SiteManagers (reference to Device Relay Address Pool).


Device Relay - Access Filter
Here we specify the IP address of the harvesting-server which are allowed to access the Device
Relay configured on the SiteManagers (reference to Device Relay Address Pool).


Server Relays - Server Target Addresses
Specifies the IP addresses of the Log Servers and other computers on the GateManager local network which may be accessed from remote devices/PLCs via a SiteManager Server Relay.

SiteManager1 Configuration
Device( Computer ) needs to initiate connection to an IP ALIAS on DEV1 port of the SiteManager (10.0.0.10 port 80)

SiteManager2 Configuration
The server relay connection to Camera

After a relay is created on the SiteManager you need to go to the GateManager and attach it.



You can now access your Camera.


For additional details see:

http://ftp.gatemanager.dk/DP_GM_SM-0020-Logging_Deployment_using_Relay_Chains.pdf