- GateManager Own - Datalogging Scenarios
- LogTunnel Scenarios
- SiteManager Embedded Scenarios
- SiteManger Scenarios
Data Collection Troubleshooting - SiteManager tools
Purpose of this article is to demonstrate useful troubleshooting tools.
- Agent
- JSON config
- Certificates
- NTP
- DCM Status
- Log view
- Status extended
- Company
- account
- GM access (LMM)
- LMM user
SiteManager
In the SiteManager there is different tools to help you troubleshoot the DCM setup:
- " DCM > Status " page is a great tool to see the overall health of your setup.
- " Log > View " is useful for tracking errors and the reason.
- " GateManager > agents " can show you if the DCM config and agents config match.
Status page (DCM > Status):
The status page consists of
An overview on the right. Here you can click to go to the corresponding section.
In the center you see various sections, the first 3 sections are a general overview of the configuration.
Subsystem configuration
Edge ID: is the device ID you enter in the IoT clouds to identify the specific device.
Store&forward database statistics
Alarms
Collectors and sample-points
Next section is all about the Collector(s)
First part is a general overview of the collector
(Here is shown overview from a collector named "sim", "sim" is also the value mentioned in the agent parameter details)
Then one section per sample-point configured for the collector.
(Here it shows that data is not reaching 2 of the 3 clouds configured,
also evident in the Alarms section)
Another example of a Collector and sample-points with error,
notice the "Inactive" status next to the headline
Data servers
First a dataserver in error state, notice the (Inactive) status and the zero's.
A second dataserver in error state, notice the 399 connection fails
And finally a working dataserver, but 2 messages hasn't reached the cloud.
Log page (Log > View):
DCM Log entry examples:
Nov 14 06:18:51 (none) user.info datasrv_aws[1094]: datasrv_aws: sawtooth: Error(-4) connecting to a1cn4k05gzdtcl-ats.iot.eu-central-1.amazonaws.com:8883 as Sc002636:demo-gm.secomea.com - will try again in 237 secs
Nov 14 06:19:53 (none) user.err collector_modbus[1097]: collector_modbus: S6116: Cannot modbus connect: Operation now in progress
Nov 14 06:22:06 (none) cron.debug ACM[1040]: Stop DCM agent 0x300040: "192.168.0.18 dcmcn=S6116 dcmpn=502"
Nov 14 06:22:06 (none) user.err ssfd[1059]: ssfd: New Alarm: Stopping collector: S6116
Nov 14 06:22:07 (none) user.info ssfd[1059]: ssfd: aws_iot: Process 1097 was killed with signal 9
Nov 14 06:22:07 (none) user.err ssfd[1059]: ssfd: aws_iot: Collector "S6116" died