--- title: "Collector SiteManager Internal" slug: "sitemanager-internal-collector" tags: ["DCM", "Data Collection Module"] updated: 2024-12-17T09:01:52Z published: 2024-12-17T09:01:52Z canonical: "kb.secomea.com/sitemanager-internal-collector" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://kb.secomea.com/llms.txt > Use this file to discover all available pages before exploring further. # Collector SiteManager Internal The purpose of this article is to serve as a reference for the Internal Collector part of the full Data Collection Module documentation. The Internal SiteManager collector is used to collect samples (data points) from a hardware SiteManager. These samples can be used in the same way as samples collected from external equipment. ## Collectable values These data values from SiteManager itself, can be collected and stored in in the DCM database and forwarded to the data servers. Values from the SiteManager hardware or firmware. | **InternalFunction** value | Unit | Description | | --- | --- | --- | | `SystemTemperature` | Centigrade/Celsius | Temperature measured in the SiteManager. | | `FreeMem` | kB | Available memory as reported by the kernel. | | `UTCRTC` | - | UTC Real Time Clock, broken into 8 separate values. | | `DigitalInput` | - | Reported as zero or one. | | `IngressRate` | bytes/s | Amount of data collected. | | `EgressRate` | bytes/s | Amount of data forwarded to data server(s). | | `DBCachesize` | bytes | Size of the database cache. | | `DBSize` | bytes | Size of the database. | Values from mobile modem, if SiteManager is XX39 model or external modem is connected. | **InternalFunction** value | Unit | Description | | --- | --- | --- | | `GSMRssi` | dBm | Received Signal Strength Indication. | | `GSMBer` | percent | Bit Error Rate. | | `GSMOperator` | string | Network operator as reported by the modem. | | `GSMTechnology` | string | For example "4G", "3G", "GPRS" etc as reported by the modem. | Values from USB GNSS unit (a.k.a GPS), if an unit is connected. | **InternalFunction** value | Unit | Description | | --- | --- | --- | | `GNSSLatitude` | decimal degrees | Positive for North, negative for South of Equator. | | `GNSSLongitude` | decimal degrees | Positive for East, negative for West of Greenwich. | | `GNSSAltitude` | meter | Height above the meas sea level (MSL). | | `GNSSSatellitesInView` | - | Number of satellites visible to the GNSS unit. | | `GNSSSatellitesUsed` | - | Number of satellites used for the position reported. | | `GNSSGeographicDistance` | meter | The Haversine geographical distance since the last GNSS position was reported. | ## Configuration The data collector configuration consist of the fields described below. ### Main section The top level of the data collector contains the following fields: | Function | Type | Importance | Description | | --- | --- | --- | --- | | **CollectorName** | string | mandatory | Unique name (within this configuration file) of a device to collect data from. (This is the name used in the agent configuration.) Follows the normal rules for names. | | **CollectorDescription** | string | optional | Description of this collector. (For your use, no system function). | | **CollectorIPAddr** | string | optional | Default IP address (or DNS name) for the device to be polled. The agent Target IP address will take precedence over this. | | **CollectorPortno** | integer > 0 and < 65535 | optional | Default port number for the device to be polled. The agent Target Port number will take precedence over this. If neither **CollectorPortno** nor agent Target Port Number is specified, the appropriate port will be used, depending on the **Protocol** parameter value. | | **Alias** | string | optional | This is the **CollectorName** of another collector, from which all the parameters (except **CollectorName**, **CollectorDescription**, **CollectorIPAddr** and **CollectorPortno**) are copied. An alias cannot refer to another alias. | | **Protocol** | string-enum | mandatory | The protocol used to collected data. Currently, 7 possible values exists: `OPC-UA/TCP`, `Modbus/TCP`, `S7/TCP`, `Http/GET`, `Rockwell`, `Simulator` and `Internal`. | | **ConnectRetryMin** | integer > 0 | mandatory | The minimum number of seconds before trying to re-establish a connection to the device being sampled. An exponential backoff algorithm is used to retry connection establishment, starting after **ConnectRetryMin** and increasing to **ConnectRetryMax**. | | **ConnectRetryMax** | integer > 0 | mandatory | The maximum number of seconds before trying to re-establish a connection to the device being sampled. | | **SamplePoints** | Array of objects | mandatory | List of samples to be collected, possibly aggregated and stored in the Store and Forward database. | ### **SamplePoints** object The **SamplePoints** objects contains the following fields: | Function | Type | Importance | Description | | --- | --- | --- | --- | | **SampleName** | string | mandatory | Name of this sampled value (sometimes called a tagname). Follows the normal rules for names. | | **SampleDescription** | string | optional | A text description of this sample value. | | **SampleUnit** | string | optional | A description of the unit measurement for this sample. | | **SampleGroup** | string | optional | Group affiliation. All sample points in the same group (in some datasrvs) should be handled (displayed) together. The DCM system itself places no meaning on this group affiliation. | | **SamplesSaved** | integer > 0 | optional | Is the number of values collected that is saved in the Store and Forward database even after the values have been sent to all dataservers. When `0` is specified, the value can be used in aggregators, but nothing is sent via dataservers to cloud system. If left unspecified, values are only saved in the Store and Forward database until they have been delivered to all dataservers. | | **OnlySaveOnChanged** | boolean | optional | Specifies if new sample values should be saved to the Store and Forward database only when the value is different from the last sample value. Default: `false`. | | **ChangeLimit** | integer/double | optional | Used if **OnlySaveOnChanged** is `true`. Specifies an amount which a sample must be greater than, to count as a changed value. This is a simple hysteresis to filter out inaccurate (jitter) measurements. Default: `0` | | **SampleDataType** | string-enum | mandatory | The type of data collected. The possible values are: `bool` (1 bit), `sbyte` (8 bit signed), `byte` (8 bit unsigned), `int16` (16 bit signed), `uint16` (16 bit unsigned), `int32` (32 signed), `uint32` (32 bit unsigned), `int64` (64 bit signed), `uint64` (64 bit unsigned), `float` (32 bit), `double` (64 bit), `string` (variable text up to 24575 bytes. Includes terminating NUL), `data` (variable data up to 24575 bytes). | | **SampleMaxVDataSize** | integer > 0 and <= 24575 | optional | The max size of variable data allowed for this sample. This is only relevant for **SampleDataType** `string` or `data`. If not specified, the value is `1024`. | | **SampleLowerLimit** | integer/double | optional | The lower limit for the collected data. If the collected data value is less than **SampleLowerLimit** it is evaluated in accordance with **SampleLimitDiscard** and **SampleLimitAlarm**. | | **SampleUpperLimit** | integer/double | optional | The upper limit for the collected data. If the collected data value is more than **SampleUpperLimit** it is evaluated in accordance with **SampleLimitDiscard** and **SampleLimitAlarm**. | | **SampleLimitDiscard** | boolean | maybe-optional | Specifies whether samples that violates the sample limit should be discarded. Mandatory if either **SampleLowerLimit** or **SampleUpperLimit** is present. | | **SampleLimitAlarm** | boolean | maybe-optional | Specifies whether samples that violates the sample limits should generate an alarm. Mandatory if either **SampleLowerLimit** or **SampleUpperLimit** is present. | | **InternalData** | object | mandatory | Specification of the internal data collection behaviour of this sample point. Mandatory if **Protocol** is `Internal`. | ### **InternalData** The **InternalData** object contains the following elements: | Function | Type | Importance | Description | | --- | --- | --- | --- | | **InternalFunction** | string-enum | mandatory | This is the internal function to be performed. The possible values are described in the [**InternalFunction** configuration](/docs/sitemanager-internal-collector#internalfunction-configuration) section. | | **InternalIndex** | integer >= 0 | maybe-optional | See the **InternalFunction** configuration section for when to use this field. | | **InternalFieldname** | string | optional | See the **InternalFunction** configuration section for when to use this field. | | **InternalSampleInterval** | integer >= 0 | mandatory | The number of seconds between each sample of this Internal object. If the interval is `0`, only event-driven polling is used. | ### **InternalFunction** configuration The chosen value of the **InternalFunction** parameter determines if other fields become **mandatory**. The chosen function also may be impacted by other fields. These dependencies is described below. | Enum value | Unit/Type | Description | | --- | --- | --- | | `SystemTemperature` | centigrade/Celsius | - | | `CPULoad` | percent | - | | `FreeMem` | kB | - | | `UTCRTC` | | **InternalIndex** becomes mandatory, and must be one of: `0` - second (0-59), `1` - minute (0-59), `2` - hour (0-23), `3` - day of the month (1-31), `4` - month (0-11, January = 0), `5` - Year (-1900), `6` - day of the week (0-6, Sunday = 0) or `7` - day of the year (0-365, 1. Jan = 0). | | `DigitalInput` | - | **InternalIndex** becomes mandatory, and must specify the index of the Digital I/O input port from which values are to be collected. | | `IngressRate` | bytes/s | **InternalFieldname** becomes a nameref for the sample for which to show the ingress rate. If not specified, the rate is the total ingress rate. | | `EgressRate` | bytes/s | **InternalFieldname** becomes the name of a data server to show the egress rate for. If not specified, the rate is the total egress rate. | | `DBCachesize` | bytes | - | | `DBSize` | bytes | - | | `GSMRssi` | dBm | - | | `GSMBer` | percent | - | | `GSMOperator` | string | - | | `GSMTechnology` | string | Possible values are: `4G`, `3G` and `GPRS` etc. | | `GNSSLatitude` | decimal degrees | The **ChangeLimit** value for this value is compared to the `GNSSGeographicDistance` value, not the value of the `GNSSLongitude`. If **OnlySaveOnChanged** is set, then **ChangeLimit** is set to the estimated precision reported by the GNSS chipset. | | `GNSSLongitude` | decimal degrees | The **ChangeLimit** value for this value is compared to the `GNSSGeographicDistance` value, not the value of the `GNSSLongitude`. If **OnlySaveOnChanged** is set, then **ChangeLimit** is set to the estimated precision reported by the GNSS chipset. | | `GNSSAltitude` | meter | If **OnlySaveOnChanged** is set, then **ChangeLimit** is set to the estimated precision reported by the GNSS chipset. | | `GNSSSatellitesInView` | - | - | | `GNSSSatellitesUsed` | - | - | | `GNSSGeographicDistance` | meter | - | Below is an example of a Internal Collector configuration: ``` { "CollectorDescription": "DCM Internal Values Collector", "CollectorName": "demointernal", "Protocol": "Internal", "SamplePoints": [ { "SampleDataType": "double", "SampleDescription": "CPU load", "SampleLimitAlarm": false, "SampleLimitDiscard": false, "SampleLowerLimit": -1000, "SampleName": "CPU", "SampleUpperLimit": 1000, "SamplesSaved": 3000000, "InternalData": { "InternalFunction": "CPULoad", "InternalSampleInterval": 1 } }, { "SampleDataType": "double", "SampleDescription": "FreeMem", "SampleLimitAlarm": false, "SampleLimitDiscard": false, "SampleLowerLimit": -1000, "SampleName": "FreeMemory", "SampleUpperLimit": 1000, "SamplesSaved": 3000000, "InternalData": { "InternalFunction": "FreeMem", "InternalSampleInterval": 1 } }, { "SampleDataType": "double", "SampleDescription": "SystemTemperature", "SampleLimitAlarm": false, "SampleLimitDiscard": false, "SampleLowerLimit": -1000, "SampleName": "SystemTemperature", "SampleUpperLimit": 1000, "SamplesSaved": 3000000, "InternalData": { "InternalFunction": "SystemTemperature", "InternalSampleInterval": 1 } } ] } ```